48 Nucleic acid extractor
A Automatic equipment of the Nucleic Acid Extraction with the function of Nucleic Acid extraction and purification, with the Nucleic Acid extraction reagent in paramagnetic particle method, which is dedicated by Corbition .bio. It is suitable for extracting high quality nucleic acid from 1-48 clinical samples and laboratory samples for downstream experiments.
* Sample injection Unique Sample Injection in Drawer type
Fast process 48 samples in 12.5mins
*Conveniencea key operation and dispense with computers
Multiple experimental programs preinstalled
Multiple samples compatible
Visual operation, real-time display of experimental progress
*Protection
Negative pressure aerosol
UV sterilization manually or automatically
* Hospital/(C)CDC : Contagious pathogens,genetic testing
* Food detection : Foodborne detection
* Environmental monitoring: Nucleic acid extraction from virus samples in the environment
* Court doctor: Sex determination, paternity test etc.
* Agriculture/Animal Husbandty: Animal and plant diseases etc.
*Scientific research: Tissue and cell suspension
Magnetic bead nucleic acid extraction kits of Corbiton M.T. are all in Preloading mode(including deep-well plate and rod comb.)
Enriched samples of extremely small amounts of nucleic acids using superparamagnetic nano-beads
Item |
Specification |
time |
CBX016 |
48texts/box preloading Fast extraction |
12.5min
|
CBX024 |
24texts/box single text preloading Fast extraction |
Please refer to Corbition for details for other available specifications.
01 Basic Parameters
Volume | 400 mm x 420 mm X 440 mm |
Weight | 25kg |
Working system | Continuously working |
Over-pressure category | Ⅱ |
Pollution level | Level 2 |
Interface | 10 inch color resistive touch screen |
Applicative consumables | 96 deep well plate; 6 strip tube; 8 strip rod comb |
Working environment | Temperature 5℃-45, Relative humidity ≤80% |
Input power | 110/220 VAC, 50/60 HZ, 750VA |
02 Performance parameter
Flux Instrument | 1-48 |
Transference type | Translational type, two stationsDispense with transferring liquid |
Magnetic bead recovery | ≥98% |
Deviations between extraction holes | <3% |
Working procedure | Built-in programs, based on user needs to create, edit, store programs |
Shock mixing speed | Fast, medium and slow for optional |
Magnetic absorption time | 0~120s set on demand |
Heating time | 0~30min set on demand |
Push-pull Base | Room for orifice plate, Avoid sputtering contamination |
Anti-pollution | Closed working environment, free from external influence; Built-in timed UV disinfection lamp, negative pressure aerosol removal |
Heating module | Built-in heating module to meet the needs of cracking, elution heating |
Intelligent monitoring | Working state alarm function during operation of equipment; Monitor the operation of the equipment at any time |
Overpressure category | Ⅱ |
Pollution level | level 2 |
reduce the losses | Single/strip, or pre-loading kit reagent consumables plate for 24/48 provided |